# OpenWebNet (BTicino/Legrand) Binding
This binding integrates BTicino / Legrand MyHOME® BUS and ZigBee wireless (MyHOME_Play®) devices using the OpenWebNet (opens new window) protocol.
The binding supports:
- both wired BUS/SCS (MyHOME) and wireless setups (MyHOME ZigBee). The two networks can be configured simultaneously
- auto discovery of BUS/SCS IP and ZigBee USB gateways; auto discovery of devices
- commands from openHAB and feedback (events) from BUS/SCS and wireless network
# Supported Things
In order for this binding to work, a BTicino/Legrand OpenWebNet gateway is needed in your home system to talk to devices.
These gateways have been tested with the binding:
IP gateways or scenario programmers, such as BTicino F454 (opens new window), MyHOMEServer1 (opens new window), MyHOME_Screen10 (opens new window), MH201 (opens new window), MH202 (opens new window), F455 (opens new window), MH200N (opens new window), F453 (opens new window), etc.
ZigBee USB Gateways, such as BTicino 3578 (opens new window), also known as Legrand 088328
NOTE The new BTicino Living Now® and Livinglight Smart® wireless systems are not supported by this binding as they do not use the OpenWebNet protocol.
The following Things and OpenWebNet WHOs
are supported:
# For BUS/SCS
Category | WHO | Thing Type IDs | Description | Status |
---|---|---|---|---|
Gateway Management | 13 | bus_gateway | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
Lighting | 1 | bus_on_off_switch , bus_dimmer | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
Automation | 2 | bus_automation | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
Temperature Control | 4 | bus_thermo_zone , bus_thermo_sensor | Thermo zones management and temperature sensors (probes). NOTE Central Units (4 or 99 zones) are not fully supported yet. See Channels - Thermo for more details. | Successfully tested: H/LN4691, KG4691; thermo sensors: L/N/NT4577 + 3455 |
Energy Management | 18 | bus_energy_meter | Energy Management | Successfully tested: F520, F521 |
# For ZigBee (Radio)
Category | WHO | Thing Type IDs | Description | Status |
---|---|---|---|---|
Gateway Management | 13 | zb_gateway | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
Lighting | 1 | zb_dimmer , zb_on_off_switch , zb_on_off_switch2u | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
Automation | 2 | zb_automation | ZigBee roller shutters |
# Discovery
Gateway and Things discovery is supported by this binding.
# BUS/SCS Discovery
- BUS Gateway automatic discovery will work only for newer gateways supporting UPnP: F454, MyHOMEServer1, MH201, MH202, MH200N, MyHOME_Screen 10. For other gateways you can add them manually, see Thing Configuration below.
- After gateway is discovered and added a connection with default password (
12345
) is tested first: if it does not work the gateway will go offline and an error status will be set. A correct password must then be set in the gateway Thing configuration otherwise the gateway will not become online. - Once the gateway is online, a second Inbox Scan will discover BUS devices
- BUS/SCS Dimmers must be ON and dimmed (30%-100%) during a Scan, otherwise they will be discovered as simple On/Off switches
- KNOWN ISSUE: In some cases dimmers connected to a F429 Dali-interface are not automatically discovered
# Discovery by Activation
BUS devices can also be discovered if activated while an Inbox Scan is active: start a new Scan, wait 15-20 seconds and then while the Scan is still active, activate the physical device (for example dim the dimmer) to have it discovered by the binding.
If a device cannot be discovered automatically it's always possible to add it manually, see Configuring Devices.
# ZigBee Discovery
The ZigBee USB Gateway must be inserted in one of the USB ports of the openHAB computer before a discovery is started
IMPORTANT NOTE: As for other openHAB bindings using the USB/serial ports, on Linux the
openhab
user must be member of thedialout
group to be able to use USB/serial port; set the group with the following command:$ sudo usermod -a -G dialout openhab
The user will need to logout and login to see the new group added. If you added your user to this group and still cannot get permission, reboot Linux to ensure the new group permission is attached to the
openhab
user.Once the ZigBee USB Gateway is added and online, a second Inbox Scan will discover devices connected to it. Because of the ZigBee radio network, device discovery will take ~40-60 sec. Be patient!
Wireless devices must be part of the same ZigBee network of the ZigBee USB Gateway to discover them. Please refer to this video by BTicino (opens new window) to setup a ZigBee wireless network which includes the ZigBee USB Gateway
Only powered wireless devices part of the same ZigBee network and within radio coverage of the ZigBee USB Gateway will be discovered. Unreachable or not powered devices will be discovered as GENERIC devices and cannot be controlled
Wireless control units cannot be discovered by the ZigBee USB Gateway and therefore are not supported
# Thing Configuration
# Configuring BUS/SCS Gateway
Configuration parameters are:
host
: IP address / hostname of the BUS/SCS gateway (String
, mandatory)- Example:
192.168.1.35
- Example:
port
: port (int
, optional, default:20000
)passwd
: gateway password (String
, required for gateways that have a password. Default:12345
)- Example:
abcde
or12345
- if the BUS/SCS gateway is configured to accept connections from the openHAB computer IP address, no password should be required
- in all other cases, a password must be configured. This includes gateways that have been discovered and added from Inbox: without a password configured they will remain OFFLINE
- Example:
discoveryByActivation
: discover BUS devices when they are activated also when a device scan is not currently active (boolean
, optional, default:false
). See Discovery by Activation.
Alternatively the BUS/SCS Gateway thing can be configured using the .things
file, see openwebnet.things
example below.
# Configuring Wireless ZigBee USB Gateway
Configuration parameters are:
serialPort
: the serial port where the ZigBee USB Gateway is connected (String
, mandatory)- Examples:
/dev/ttyUSB0
(Linux/RaPi),COM3
(Windows)
- Examples:
Alternatively the ZigBee USB Gateway thing can be configured using the .things
file, see openwebnet.things
example below.
# Configuring Devices
Devices can be discovered automatically using an Inbox Scan after a gateway has been configured and connected. For any manually added device, you must configure:
- the associated gateway (
Parent Bridge
menu) - the
where
config parameter (OpenWebNet Device Address
):- example for BUS/SCS device with WHERE address Point to Point
A=2 PL=4
-->where="24"
- example for BUS/SCS device with WHERE address Point to Point
A=03 PL=11
on local bus -->where="0311#4#01"
- example for ZigBee devices:
where=765432101#9
. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for exampleID 0074CBB1
: convert to decimal (7654321
) and add01#9
at the end to obtainwhere=765432101#9
. For 2-unit switch devices (zb_on_off_switch2u
), last part should be00#9
.
- example for BUS/SCS device with WHERE address Point to Point
# Configuring Thermo
In BTicino MyHOME Thermoregulation (WHO=4) each zone has associated a thermostat, additional temperature sensors (optional), actuators and heating/conditioning valves. A zone is associated to at least one thermostat and one actuator.
Thermo zones can be configured defining a bus_thermo_zone
Thing for each zone with the following parameters:
- the
where
config parameter (OpenWebNet Device Address
):- example BUS/SCS Thermo
zone=1
-->where="1"
- example BUS/SCS Thermo
- the
standAlone
config parameter (boolean
, default:true
): identifies if the zone is managed or not by a Central Unit (4 or 99 zones).standAlone=true
means no Central Unit is present in the system.
Temperature sensors can be configured defining a bus_thermo_sensor
Thing with the following parameters:
- the
where
config parameter (OpenWebNet Device Address
):- example sensor
5
of external zone00
-->where="500"
- example: slave sensor
3
of zone2
-->where="302"
- example sensor
# NOTE
Systems with Central Units (4 or 99 zones) are not fully supported yet.
# Channels
# Lighting, Automation and Power meter channels
Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
---|---|---|---|---|
switch or switch_01 /02 for ZigBee | bus_on_off_switch , zb_on_off_switch , zb_on_off_switch2u | Switch | To switch the device ON and OFF | R/W |
brightness | bus_dimmer , zb_dimmer | Dimmer | To adjust the brightness value (Percent, ON , OFF ) | R/W |
shutter | bus_automation | Rollershutter | To activate roller shutters (UP , DOWN , STOP , Percent - see Shutter position) | R/W |
power | bus_energy_meter | Number:Power | The current active power usage from Energy Meter | R |
# Thermo channels
Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
---|---|---|---|---|---|
temperature | bus_thermo_zone , bus_thermo_sensor | Number:Temperature | The zone currently sensed temperature | R | N |
setpointTemperature | bus_thermo_zone | Number:Temperature | The zone setpoint temperature | R/W | N |
function | bus_thermo_zone | String | The zone set thermo function: COOLING , HEATING or GENERIC (heating + cooling) | R/W | N |
mode | bus_thermo_zone | String | The zone set mode: MANUAL , PROTECTION , OFF | R/W | N |
speedFanCoil | bus_thermo_zone | String | The zone fancoil speed: AUTO , SPEED_1 , SPEED_2 , SPEED_3 | R/W | N |
actuators | bus_thermo_zone | String | The zone actuator(s) status: OFF , ON , OPENED , CLOSED , STOP , OFF_FAN_COIL , ON_SPEED_1 , ON_SPEED_2 , ON_SPEED_3 , OFF_SPEED_1 , OFF_SPEED_2 , OFF_SPEED_3 | R | Y |
heatingValves | bus_thermo_zone | String | The zone heating valve(s) status: OFF , ON , OPENED , CLOSED , STOP , OFF_FAN_COIL , ON_SPEED_1 , ON_SPEED_2 , ON_SPEED_3 , OFF_SPEED_1 , OFF_SPEED_2 , OFF_SPEED_3 | R | Y |
conditioningValves | bus_thermo_zone | String | The zone conditioning valve(s) status: OFF , ON , OPENED , CLOSED , STOP , OFF_FAN_COIL , ON_SPEED_1 , ON_SPEED_2 , ON_SPEED_3 , OFF_SPEED_1 , OFF_SPEED_2 , OFF_SPEED_3 | R | Y |
# Notes on channels
# shutter
position
For Percent commands and position feedback to work correctly, the shutterRun
Thing config parameter must be configured equal to the time (in ms) to go from full UP to full DOWN.
It's possible to enter a value manually or set shutterRun=AUTO
(default) to calibrate shutterRun
automatically: in this case a UP >> DOWN >> Position% cycle will be performed automatically the first time a Percent command is sent to the shutter.
- if
shutterRun
is not set, or is set toAUTO
but calibration has not been performed yet, then position estimation will remainUNDEF
(undefined) - if
shutterRun
is wrongly set higher than the actual runtime, then position estimation will remainUNDEF
: try to reduce shutterRun until you find the right value - before adding/configuring roller shutter Things it is suggested to have all roller shutters
UP
, otherwise the Percent command won’t work until the roller shutter is fully rolled up - if OH is restarted the binding does not know if a shutter position has changed in the meantime, so its position will be
UNDEF
. Move the shutter allUP
/DOWN
to synchronize again its position with the binding - the shutter position is estimated based on UP/DOWN timing: an error of ±2% is normal
# Full Example
# openwebnet.things:
BUS gateway and things configuration:
Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", passwd="abcde", port=20000, discoveryByActivation=false ] {
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="0311#4#01" ]
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
bus_energy_meter CENTRAL_Ta "Energy Meter Ta" [ where="51" ]
bus_energy_meter CENTRAL_Tb "Energy Meter Tb" [ where="52" ]
bus_thermo_zone LR_zone "Living Room Zone" [ where="2"]
bus_thermo_sensor EXT_tempsensor "External Temperature" [ where="500"]
}
ZigBee USB Gateway and things configuration - for radio devices:
Bridge openwebnet:zb_gateway:myZBgateway [ serialPort="COM3" ] {
zb_dimmer myZB_dimmer [ where="765432101#9"]
zb_on_off_switch myZB_switch [ where="765432201#9"]
zb_on_off_switch2u myZB_2U_switch [ where="765432300#9"]
}
# openwebnet.items:
Example items linked to BUS devices:
NOTE: lights, blinds and zones (thermostat) can be handled from personal assistants (Google Home, Alexa). In the following example Google Assistant
was configured (ga="..."
) according to the official documentation (opens new window).
Switch iLR_switch "Light" (gLivingRoom) { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch", ga="Light" }
Dimmer iLR_dimmer "Dimmer [%.0f %%]" (gLivingRoom) { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness", ga="Light" }
Rollershutter iLR_shutter "Shutter [%.0f %%]" (gShutters, gLivingRoom) { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter", ga="Blinds" }
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
Group gLivingRoomZone "Living Room Zone" { ga="Thermostat" [ modes="auto=GENERIC,heat=HEATING,cool=COOLING", thermostatTemperatureRange="7,35", useFahrenheit=false ] }
Number:Temperature iLR_zone_temp "Temperature [%.1f %unit%]" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:temperature", ga="thermostatTemperatureAmbient" }
Number:Temperature iLR_zone_setTemp "SetPoint Temperature" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:setpointTemperature", ga="thermostatTemperatureSetpoint" }
String iLR_zone_fanSpeed "FanSpeed" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:speedFanCoil" }
String iLR_zone_mode "Mode" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:mode" }
String iLR_zone_func "Function" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:function", ga="thermostatMode" }
String iLR_zone_actuators "Actuators" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:actuators" }
String iLR_zone_hv "Heating valves" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:heatingValves" }
String iLR_zone_cv "Conditioning valves" (gLivingRoomZone) { channel="openwebnet:bus_thermo_zone:mybridge:LR_zone:conditioningValves" }
Number:Temperature iEXT_temp "Temperature [%.1f %unit%]" (gExternal) { channel="openwebnet:bus_thermo_sensor:mybridge:EXT_tempsensor:temperature" }
Example items linked to OpenWebNet ZigBee devices:
Dimmer iDimmer "Dimmer [%.0f %%]" <DimmableLight> (gKitchen) [ "Lighting" ] { channel="openwebnet:zb_dimmer:myZBgateway:myZB_dimmer:brightness" }
Switch iSimpleSwitch "Kitchen Switch" <light> (gKitchen) [ "Lighting" ] { channel="openwebnet:zb_on_off_switch:myZBgateway:myZB_switch:switch_01" }
Switch iSwitch_01 "2U first light" <light> (gKitchen) [ "Lighting" ] { channel="openwebnet:zb_on_off_switch2u:myZBgateway:myZB_2U_switch:switch_01" }
Switch iSwitch_02 "2U second light" <light> (gKitchen) [ "Lighting" ] { channel="openwebnet:zb_on_off_switch2u:myZBgateway:myZB_2U_switch:switch_02" }
# openwebnet.sitemap
sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
{
Frame label="Living Room"
{
Default item=iLR_switch icon="light"
Default item=iLR_dimmer icon="light"
Default item=iLR_shutter
}
Frame label="Energy Meters" icon="energy"
{
Default item=iCENTRAL_Ta label="General" icon="energy" valuecolor=[>3000="red"]
Default item=iCENTRAL_Tb label="Ground Floor" icon="energy" valuecolor=[>3000="red"]
}
Frame label="Living Room Thermo"
{
Default item=iLR_zone_temp label="Temperature" icon="fire" valuecolor=[<20="red"]
Setpoint item=iLR_zone_set label="Setpoint [%.1f °C]" step=0.5 minValue=15 maxValue=30
Selection item=iLR_zone_fanSpeed label="Fan Speed" icon="fan" mappings=[AUTO="AUTO", SPEED_1="Low", SPEED_2="Medium", SPEED_3="High"]
Switch item=iLR_zone_mode label="Mode" icon="settings"
Selection item=iLR_zone_func label="Function" icon="heating" mappings=[HEATING="Heating", COOLING="Cooling", GENERIC="Heating/Cooling"]
Default item=iLR_zone_actuators label="Actuators status"
Default item=iLR_zone_hv label="Heating valves status"
Default item=iLR_zone_cv label="Conditioning valves status"
}
}
# Notes
- The OpenWebNet protocol is maintained and Copyright by BTicino/Legrand. The documentation of the protocol if freely accessible for developers on the Legrand developer web site (opens new window)
# Special thanks
Special thanks for helping on testing this binding go to: @m4rk (opens new window), @bastler (opens new window), @gozilla01 (opens new window), @enrico.mcc (opens new window), @k0nti (opens new window), @gilberto.cocchi (opens new window), @llegovich (opens new window), @gabriele.daltoe (opens new window), @feodor (opens new window), @aconte80 (opens new window) and many others at the fantastic openHAB community!